Corrosion and Deposit Monitor - Test Unit Model: CMS-CDM

Main Features

  • Compact & Portable
  • Digital Readout of temperature
  • Easy to use
  • Easy to Install
  • On-Line :Visual Inspection of deposit
  • Off-Line : Quantitative by weighing heat transfer surface
  • Measurements: Deposit weight & average weight per unit surface area – Offline measurement
  • Online installation in Annular flow conditions for the monitoring of scale deposition
  • System Details

    The CMS-CDM is a small compact and portable system designed for ‘Corrosion and Deposit monitoring’ application. Model CMS-CDM includes,

  • Frame, panel, valve, flow switch, flow meter, specimen holder and heat exchange assembly, temperature controller and corrosion coupon holder.
  • Pipe material is 3/4" Schedule 80 PVC.
  • A digital display of temperatures of - inlet water, skin temperature
  • The sampling unit consists of a glass tube and a 600 watt heater.
  • Brief Functional details of the system

    The heating of the sample tube accelerates the rate of deposition in the sample tube. The increase in the Deposition provides an idea of the amount of deposit formation over a long period of time. The user can set a minimum pressure drop of 10 psi to maintain flow through the tubing and sample tube holder. Water flow and heating temperature can be set manually to simulate the field cooling water conditions.

  • The heating of the sample tube accelerates the rate of deposition in the sample tube. The increase in the Deposition provides an idea of the amount of deposit formation over a long period of time. The user can set a minimum pressure drop of 10 psi to maintain flow through the tubing and sample tube holder. Water flow and heating temperature can be set manually to simulate the field cooling water conditions.
  • The sample tube holder is designed suitable to a operating at
  • 60 psi at 600C for 2 hours.
  • 30 psi at 450C for 6 hours.
  • 10 psi at 290C for 12 hours.
  • Caution: Higher pressures above 80 psi may cause leaks at the tube fittings.

    System Block Diagram of Model CMS-CDM

  • Test Heat Exchanger Tube
  • Water Temperature - Outgoing
  • Tube Heater Temperature probe
  • Sample Tube
  • Corrosion Coupon
  • Flow Meter
  • Sample Port
  • Water Temperature Probe - Inlet
  • Shut-Off Valve
  • Frame
  • 3/4" Water Inlet Port
  • 3/4" (1.91 cm) Water Outlet Port
  • Temperature Controller and Display
  • Electrical Input 240 VAC, 50/60 Hz
    Heater Power Maximum 600 watts; 2.5 Amp
    Frame material SS316 sheet with SS316 Angles / square bars
    Flow switch 4 LPM
    Pipe material Sch 80 PVC
    Panel material Polyethylene
    Maximum pressure 60 psi
    Max. temperature 600C
    Net Weight 14.00 kg
    Dimensions W 21.00” x H 27.00” x D 7”
    Measurements On-Line :Visual Inspection of scales/ deposit
    Off-Line : Quantitative by weighing heat transfer surface
    Measurement: Deposit weight & average weight per unit surface area – Offline measurement
    Online installation in Annular flow conditions for the monitoring of scale deposition and Corrosion
    Off-Line Corrosion Rate measurement by weight loss Coupon method
    Optional LPR Probe With Handheld Meter
    Variety of Coupon Material with Material test report.
    On-Line ORP measurement
    Online pH measurement